ESD Wrist Straps (Anti-Static Wrist Straps) with 1 MΩ Grounding Cords

An ESD wrist strap, also called an anti-static wrist strap or grounding wrist strap, keeps the operator at the same potential as the anti-static workbench, so static charge drains away before it can reach a board or component. Each of our corded anti-static wrist straps is a conductive wrist band with a snap and a PU coiled ground cord with a built-in 1 MΩ current-limiting resistor. The cord ends in a banana plug with a removable alligator clip, so it plugs into a common point ground or clips onto a grounding point.

Fabric, metal expansion and cordless ESD wrist straps side by side

Left to right: fabric band with coil cord, metal expansion band with coil cord, cordless band.

Types of ESD wrist straps

TypeBandCoil cordCord lengthBest for
Standard single-wire anti-static wrist strap (blue / red)Elastic band with 4 stainless-steel conductive yarns; slide-lock adjustmentPU, Ø 2.2 mm, 6-strand conductor1.8 / 2.5 / 3.0 mGeneral electronics assembly and repair benches
Buckle-adjust single-wire (blue)4 stainless-steel + 1 silver conductive yarn; buckle adjustmentPU, Ø 2.4 mm, 7-strand copper conductor1.8 / 2.5 / 3.0 mOperators who want a firmer, buckle-adjusted fit
Silicone band (blue)Silicone band, 6-position adjustment; easy to wipe cleanPU, Ø 2.5 mm, 7-strand copper conductor1.8 / 2.5 / 3.0 mCleanrooms and areas where fabric bands are not wanted
Dual-wire ESD wrist strap (black)Band with 12 silver conductive yarns, two snapsPU, Ø 2.2 mm, dual conductor1.8 / 2.5 / 3.0 mLines that use a continuous wrist strap monitor
Metal ESD wrist strap (stainless-steel expansion band)Stainless-steel expansion band, no buckle; fits most wrist sizes and wipes cleanPU, Ø 2.4 mm (measured 2.42 mm)2.5 mOperators who prefer a metal band; shared stations

High Quality L Type PU 1.8 Meters Earth Anti-Static ESD Wrist Strap Dual Bench Grounding Socket Plug for Industrial Antistatic

ESD  heel straps allow freedom of movement around the shop environment without the restriction of a wrist strap ground cord leashing you to a bench.

Product name
ESD Wrist Strap
Color
Blue,black,red,
Material
White yarn+pvc
wire length
1.8M,2.2m,2.4m
Diameter of wire
2.0mm
Application
Electornic product manufacture process
MOQ
100 Pcs
Package
1 pcs/bag
wrist band
adjustable
Surface Resistance
≤800 k(Ω)
ItemSpecification
Cord resistor1 MΩ, built into the cord
Cord materialPU coiled cord, high-recovery coil
Cord lengths1.8 / 2.5 / 3.0 m (metal expansion band: 2.5 m)
Ground endBanana plug with removable alligator clip
BandsFabric (blue, red, green, black), silicone, stainless-steel expansion band (others for OEM)
OEMCustom colours, cord length, logo and packaging for bulk orders

ESD wrist strap resistance: test results

Independent laboratory test of our corded wrist strap, commissioned by HORBEST in 2026 (report UK2000707090). Three samples, 10 V, 24.8 °C, 51 %RH:

MeasurementRequirement in the reportSample 1Sample 2Sample 3
System resistance (strap worn, operator holding electrode)7.5 × 10⁵ – 1 × 10⁷ Ω1.18 × 10⁶ Ω1.18 × 10⁶ Ω1.19 × 10⁶ Ω
Band inner surface to snap≤ 1 × 10⁵ Ω1.10 × 10³ Ω1.09 × 10³ Ω1.08 × 10³ Ω
Ground cord, end to end7.5 × 10⁵ – 1 × 10⁷ Ω9.20 × 10⁵ Ω9.28 × 10⁵ Ω9.34 × 10⁵ Ω

Our own check (28 October 2026)

We repeated two measurements in-house with an ACL Model 800 megohmmeter (SN R01172234, calibrated 19 August 2026):

MeasurementHowResultConditions
System resistanceFabric strap worn on bare skin, cord connected to the meter, operator gripping a weighted electrode9.55 × 10⁶ Ω55.8 %RH, 29.2 °C
Strap only (inside of band to plug)Metal expansion band on a foil-wrapped cylinder9.58 × 10⁵ Ω57.8 %RH, 29.0 °C

System resistance includes the operator’s skin, so it varies from person to person and with how dry the skin is. A tight band on bare skin gives the most stable reading.

ESD wrist strap ground cord with banana plug and removable alligator clip

Banana plug with removable alligator clip.

Digital caliper measuring the PU coil cord of an ESD wrist strap at 2.42 mm

PU cord measured at 2.42 mm.

Tested resistance

Independent laboratory test of our corded wrist strap, commissioned by HORBEST in 2026 (report UK2000707090). Three samples, 10 V, 24.8 °C, 51 %RH:

MeasurementRequirement in the reportSample 1Sample 2Sample 3
System resistance (strap worn, operator holding electrode)7.5 × 10⁵ – 1 × 10⁷ Ω1.18 × 10⁶ Ω1.18 × 10⁶ Ω1.19 × 10⁶ Ω
Band inner surface to snap≤ 1 × 10⁵ Ω1.10 × 10³ Ω1.09 × 10³ Ω1.08 × 10³ Ω
Ground cord, end to end7.5 × 10⁵ – 1 × 10⁷ Ω9.20 × 10⁵ Ω9.28 × 10⁵ Ω9.34 × 10⁵ Ω

Our own check (28 October 2026)

We repeated two measurements in-house with an ACL Model 800 megohmmeter (SN R01172234, calibrated 19 August 2026):

MeasurementHowResultConditions
System resistanceFabric strap worn on bare skin, cord connected to the meter, operator gripping a weighted electrode9.55 × 10⁶ Ω55.8 %RH, 29.2 °C
Strap only (inside of band to plug)Metal expansion band on a foil-wrapped cylinder9.58 × 10⁵ Ω57.8 %RH, 29.0 °C

System resistance includes the operator’s skin, so it varies from person to person and with how dry the skin is. A tight band on bare skin gives the most stable reading.

ACL Model 800 cuff-to-plug resistance test of a metal ESD wrist strap reading 9.58 x 10^5 ohms

Strap only: 9.58 × 10⁵ Ω

ACL Model 800 system resistance test of an ESD wrist strap reading 9.55 x 10^6 ohms

System test: 9.55 × 10⁶ Ω

How to use an anti-static wrist strap

ESD wrist strap worn snugly on bare skin with coiled ground cord
  1. Wear the band directly on bare skin, snug enough that it does not slide.
  2. Snap the cord onto the band and plug the other end into the bench’s common point ground.
  3. Check the strap with a wrist strap tester at the start of every shift.

Full guide: how anti-static wrist straps work and how to wear one · Testing: how to test an ESD wrist strap · Continuous checking: ESD wrist strap monitor

Cordless wrist band

For office, home and on-site work where there is no ground point to plug into, we also supply a wireless anti-static wrist strap (cordless band). To discharge, touch the screw on the band housing to a grounded metal object. For seated work at an ESD workstation, use a corded strap.

ESD wrist strap FAQ

Why does an ESD wrist strap have a 1 MΩ resistor?

The 1 MΩ resistor in the cord limits the current that could flow through the operator if they touch a live voltage, while still letting static charge drain to ground quickly.

Where do you clip an anti-static wrist strap?

At an ESD workstation, plug the banana plug into the common point ground on the bench or mat. Without a workstation, clip the alligator clip to a grounded point, such as bare unpainted metal on a grounded equipment frame.

Metal or fabric band?

Both work the same way. Fabric bands are light and adjustable; the metal expansion band has no buckle, fits most wrists and wipes clean, which suits shared stations.

Can I use an anti-static wrist strap for PC building?

Yes. Clip the cord to bare unpainted metal on the computer case before you handle memory, drives or the motherboard. For occasional home jobs a cordless band is an option.

Bulk and OEM anti-static wrist straps: tell us the type, cord length, colour and quantity, and we will reply with a quote and lead time. Request a quote
 

📞 Contact Us Today

For bulk orders, quotes, or product guidance, get in touch with our expert team:

Email: sales2@esdbest.com