An ESD wrist strap, also called an anti-static wrist strap or grounding wrist strap, keeps the operator at the same potential as the anti-static workbench, so static charge drains away before it can reach a board or component. Each of our corded anti-static wrist straps is a conductive wrist band with a snap and a PU coiled ground cord with a built-in 1 MΩ current-limiting resistor. The cord ends in a banana plug with a removable alligator clip, so it plugs into a common point ground or clips onto a grounding point.
Left to right: fabric band with coil cord, metal expansion band with coil cord, cordless band.
| Type | Band | Coil cord | Cord length | Best for |
|---|---|---|---|---|
| Standard single-wire anti-static wrist strap (blue / red) | Elastic band with 4 stainless-steel conductive yarns; slide-lock adjustment | PU, Ø 2.2 mm, 6-strand conductor | 1.8 / 2.5 / 3.0 m | General electronics assembly and repair benches |
| Buckle-adjust single-wire (blue) | 4 stainless-steel + 1 silver conductive yarn; buckle adjustment | PU, Ø 2.4 mm, 7-strand copper conductor | 1.8 / 2.5 / 3.0 m | Operators who want a firmer, buckle-adjusted fit |
| Silicone band (blue) | Silicone band, 6-position adjustment; easy to wipe clean | PU, Ø 2.5 mm, 7-strand copper conductor | 1.8 / 2.5 / 3.0 m | Cleanrooms and areas where fabric bands are not wanted |
| Dual-wire ESD wrist strap (black) | Band with 12 silver conductive yarns, two snaps | PU, Ø 2.2 mm, dual conductor | 1.8 / 2.5 / 3.0 m | Lines that use a continuous wrist strap monitor |
| Metal ESD wrist strap (stainless-steel expansion band) | Stainless-steel expansion band, no buckle; fits most wrist sizes and wipes clean | PU, Ø 2.4 mm (measured 2.42 mm) | 2.5 m | Operators who prefer a metal band; shared stations |
High Quality L Type PU 1.8 Meters Earth Anti-Static ESD Wrist Strap Dual Bench Grounding Socket Plug for Industrial Antistatic
ESD heel straps allow freedom of movement around the shop environment without the restriction of a wrist strap ground cord leashing you to a bench.
Product name | ESD Wrist Strap |
Color | Blue,black,red, |
Material | White yarn+pvc |
wire length | 1.8M,2.2m,2.4m |
Diameter of wire | 2.0mm |
Application | Electornic product manufacture process |
MOQ | 100 Pcs |
Package | 1 pcs/bag |
wrist band | adjustable |
Surface Resistance | ≤800 k(Ω) |
| Item | Specification |
|---|---|
| Cord resistor | 1 MΩ, built into the cord |
| Cord material | PU coiled cord, high-recovery coil |
| Cord lengths | 1.8 / 2.5 / 3.0 m (metal expansion band: 2.5 m) |
| Ground end | Banana plug with removable alligator clip |
| Bands | Fabric (blue, red, green, black), silicone, stainless-steel expansion band (others for OEM) |
| OEM | Custom colours, cord length, logo and packaging for bulk orders |
Independent laboratory test of our corded wrist strap, commissioned by HORBEST in 2026 (report UK2000707090). Three samples, 10 V, 24.8 °C, 51 %RH:
| Measurement | Requirement in the report | Sample 1 | Sample 2 | Sample 3 |
|---|---|---|---|---|
| System resistance (strap worn, operator holding electrode) | 7.5 × 10⁵ – 1 × 10⁷ Ω | 1.18 × 10⁶ Ω | 1.18 × 10⁶ Ω | 1.19 × 10⁶ Ω |
| Band inner surface to snap | ≤ 1 × 10⁵ Ω | 1.10 × 10³ Ω | 1.09 × 10³ Ω | 1.08 × 10³ Ω |
| Ground cord, end to end | 7.5 × 10⁵ – 1 × 10⁷ Ω | 9.20 × 10⁵ Ω | 9.28 × 10⁵ Ω | 9.34 × 10⁵ Ω |
We repeated two measurements in-house with an ACL Model 800 megohmmeter (SN R01172234, calibrated 19 August 2026):
| Measurement | How | Result | Conditions |
|---|---|---|---|
| System resistance | Fabric strap worn on bare skin, cord connected to the meter, operator gripping a weighted electrode | 9.55 × 10⁶ Ω | 55.8 %RH, 29.2 °C |
| Strap only (inside of band to plug) | Metal expansion band on a foil-wrapped cylinder | 9.58 × 10⁵ Ω | 57.8 %RH, 29.0 °C |
System resistance includes the operator’s skin, so it varies from person to person and with how dry the skin is. A tight band on bare skin gives the most stable reading.
Banana plug with removable alligator clip.
PU cord measured at 2.42 mm.
Independent laboratory test of our corded wrist strap, commissioned by HORBEST in 2026 (report UK2000707090). Three samples, 10 V, 24.8 °C, 51 %RH:
| Measurement | Requirement in the report | Sample 1 | Sample 2 | Sample 3 |
|---|---|---|---|---|
| System resistance (strap worn, operator holding electrode) | 7.5 × 10⁵ – 1 × 10⁷ Ω | 1.18 × 10⁶ Ω | 1.18 × 10⁶ Ω | 1.19 × 10⁶ Ω |
| Band inner surface to snap | ≤ 1 × 10⁵ Ω | 1.10 × 10³ Ω | 1.09 × 10³ Ω | 1.08 × 10³ Ω |
| Ground cord, end to end | 7.5 × 10⁵ – 1 × 10⁷ Ω | 9.20 × 10⁵ Ω | 9.28 × 10⁵ Ω | 9.34 × 10⁵ Ω |
We repeated two measurements in-house with an ACL Model 800 megohmmeter (SN R01172234, calibrated 19 August 2026):
| Measurement | How | Result | Conditions |
|---|---|---|---|
| System resistance | Fabric strap worn on bare skin, cord connected to the meter, operator gripping a weighted electrode | 9.55 × 10⁶ Ω | 55.8 %RH, 29.2 °C |
| Strap only (inside of band to plug) | Metal expansion band on a foil-wrapped cylinder | 9.58 × 10⁵ Ω | 57.8 %RH, 29.0 °C |
System resistance includes the operator’s skin, so it varies from person to person and with how dry the skin is. A tight band on bare skin gives the most stable reading.
Strap only: 9.58 × 10⁵ Ω
System test: 9.55 × 10⁶ Ω
Full guide: how anti-static wrist straps work and how to wear one · Testing: how to test an ESD wrist strap · Continuous checking: ESD wrist strap monitor
For office, home and on-site work where there is no ground point to plug into, we also supply a wireless anti-static wrist strap (cordless band). To discharge, touch the screw on the band housing to a grounded metal object. For seated work at an ESD workstation, use a corded strap.
The 1 MΩ resistor in the cord limits the current that could flow through the operator if they touch a live voltage, while still letting static charge drain to ground quickly.
At an ESD workstation, plug the banana plug into the common point ground on the bench or mat. Without a workstation, clip the alligator clip to a grounded point, such as bare unpainted metal on a grounded equipment frame.
Both work the same way. Fabric bands are light and adjustable; the metal expansion band has no buckle, fits most wrists and wipes clean, which suits shared stations.
Yes. Clip the cord to bare unpainted metal on the computer case before you handle memory, drives or the motherboard. For occasional home jobs a cordless band is an option.
📞 Contact Us Today
For bulk orders, quotes, or product guidance, get in touch with our expert team:
Email: sales2@esdbest.com