Self-Cleaning Ionizer Fan

Self-Cleaning Ionizer Fan

Fan alarm

The indicator light is on when the fun is stuck or doesn’t rotate; meanwhile, the buzzer sends out alarm sound.

Fan air flow

Low speed: 60 CFM / 2.5 m/sHigh speed: 150 CFM / 6.0 m/s

Voltage regulation mode/ applied voltage

high frequency AC method/2200V

Ion balance

Within ±10V (measuring distance 300mm)

Destaticizing time

Within 0.3s (measuring distance 300mm)

Cleaning timer set time

Can set within 1-999 hours

Ozone generation amount (ppm)

Within 0.03ppm (measuring distance 150mm)

Service environment SJt

-10℃ to +50℃

Service environment humidity

<60% (no condensation)

Overall size/mm

215mm (L) × 100mm (W) × 230mm (H)

Weight/Kg

2.5Kg

Working Principle of Self-Cleaning Ionizer Fan
 
The HB1201E Single-Head DC Self-Cleaning Ionizer Fan utilizes an internationally advanced closed-loop control system. The circuit automatically adjusts the output of positive and negative ions based on the voltage detected by the sensor (metal mesh cover) located at the fan outlet. This ensures excellent ion balance across a wide temperature and humidity range.
 
Product Features of Self-Cleaning Ionizer Fan
 
The HB1201E DC Self-Cleaning Ionizer Fan is a self-cleaning model in the ionizer fan series. Featuring a benchtop design, Self-Cleaning Ionizer Fan effectively neutralizes static charges across the entire working area used by a single operator. Ionizer Fan self-cleaning emitter function ensures long-term performance and reduces maintenance needs.
 
Technical Specifications of Self-Cleaning Ionizer Fan
 
Item                                           Specification of Self-Cleaning Ionizer Fan
Power Consumption                                      ≤30W
Input Voltage                                              220V / 50Hz
Current Consumption                              2A (at maximum airflow)
Air Volume                                             Low speed: 60 CFM / 2.5 m/sHigh speed: 150 CFM / 6.0 m/s
Effective Coverage Area                        300mm × 300mm × 900mm
Ozone Emission                                     <0.03 PPM (measured at 15 cm from the fan)
Operating Temperature                         -10℃ to +50℃
Dimensions (without bracket)               154mm (L) × 85mm (W) × 203mm (H)
Dimensions (with bracket)                    215mm (L) × 100mm (W) × 230mm (H)
Offset Voltage (Residual Voltage)        ≤±5V (measured at 300mm–600mm)
Weight                                                 2.5 kg
Housing Material                                 Cold-rolled steel
Surface Treatment                               Baked enamel finish
 
 
Static Elimination Test Results of Self-Cleaning Ionizer Fan
 
Test Conditions:
•Test Voltage: 1kV to 100V
•Ambient Temperature: 22℃
•Relative Humidity: ≤60%
 
Distance Decay Time (Positive) Decay Time (Negative) Residual Voltage
300mm 0.3s 0.4s ≤±5V
600mm 0.7s 0.8s ≤±5V
 
Notes:
•The ion balance and decay time of the HB1201E meet ESD standards.
•Decay time is measured from 1000V to 100V.
•All data are based on results from the ME268A Electrostatic Comprehensive Tester.
•Actual performance may vary with changes in ambient temperature and humidity.
 

📞 Contact Us Today

For bulk orders, quotes, or product guidance, get in touch with our expert team:

Email: sales2@esdbest.com
Phone: +86 137 1427 2599