Mini Ioniser

Mini Ioniser

Fan alarm

Alternative version (formal/technical):
If the fan becomes jammed or stops rotating, the indicator light activates and an audible alarm is triggered.

Fan air flow

50 CFM / 2.5 m/s

Voltage regulation mode/ applied voltage

high frequency AC method/2200V

Ion balance

Within ±10V (measuring distance 300mm)

Destaticizing time

Within 5s (measuring distance 300mm)

Cleaning timer set time

Can set within 1-999 hours

Ozone generation amount (ppm)

Within 0.03ppm (measuring distance 150mm)

Service environment SJt

-10℃ to +50℃

Service environment humidity

< 60% (no condensation)

Overall size/mm

75mm (L) × 47mm (W) × 92mm (H) (including bracket)

Weight/Kg

1.5Kg

Ionizer fan’s Product Features
 
The HB1201C Mini DC Ionizer fan is the smallest model in the ionizer fan series. This single-head DC ionizing fans features a benchtop design, capable of neutralizing static electricity across the entire working area used by a single operator. With its ultra-compact size, lightweight, and portable design, it provides stable ion balance but does not include an ion output regulator.
 
The HB1201C utilizes an internationally advanced closed-loop control system. The circuit automatically adjusts the amount of positive and negative ions based on the voltage detected by the sensor located at the fan outlet, ensuring excellent ion balance performance.
 
Technical Specifications of ionizer fan
 
Item                                     Specification
Power Consumption             ≤10W
Input Voltage                        220V/50Hz or 110V/60Hz
Current Consumption           0.04A (at maximum airflow)
Airflow                                  High speed: 50 CFM / 2.5 m/s
Effective Coverage Area      200mm × 200mm × 500mm
Ozone Emission                  <0.03 PPM (measured at 15 cm from the fan)
Operating Temperature        -10℃ to +50℃
Dimensions                         75mm (L) × 47mm (W) × 92mm (H) (including bracket)
Offset Voltage (Residual Voltage):   ≤±20V (measured at 300mm)
Weight                                 0.5 kg
Housing Material                Stainless Steel
 
 
Static Elimination Test Results of ionizer fan
 
Test Conditions
•Test Voltage: 1kV to 100V
•Ambient Temperature: 22℃
•Humidity: ≤60%
•Distance: 300mm
 
Measurement                            Result
Decay Time (Positive)               ≤5s
Decay Time (Negative)             ≤5s
Residual Voltage (Positive)       ≤±20V
Residual Voltage (Negative)      ≤±20V